Economical equivalent membranes with quick delivery for replacement in water and wastewater treatment projects.

Products >> Hollow Fiber UF Membrane Module >> PVDF UF Membrane Module

  • Pall Ultra60 MSA-620A Equivalent
Pall Ultra60 MSA-620A Equivalent

Pall Ultra60 MSA-620A Equivalent

Equivalent, equivalence, replacement, alternative, analog, retrofit, analogue, derivative, substitution to: Pall Ultra60 MSA-620A UF membrane module

Equivalent Comparison Chart

Parameters

Module

Equivalent Module

Model

Pall Ultra60 MSA-620A

TFMSA-60A

Dimensions

D 178 mm, L 2332 mm

D 178 mm, L 2332 mm

Membrane Material

PVDF (polyvinylidene fluoride)

PVDF (polyvinylidene fluoride)

Pore Size

0.01 µm

0.01 µm

Membrane Area

60 m2

60 m2

Flow Direction

Outside-in

Outside-in

Type of operation

Dead-end flow

Dead-end flow

General Information

TFMSA-60A is manufactured as the equivalent, replacement, alternative, retrofit and analogue to Pall Ultra60 MSA-620A UF membrane module.
TFMSA-60A ultrafiltration (UF) membrane module is a pressurized module, which is developed and manufactured for the filtration of surface water, potable water, seawater and industrial wastewater. These UF modules are made of new generation PVDF hollow fiber membrane with high fouling resistance and hydrophilicity.
TFMSA-60A UF module is applied in new systems, as well as directly connected to existing UF systems as replacements, providing high-quality filtrate by removing suspended solids, colloids, pyrogens, bacteria, viruses and other impurities to protect downstream processes.

Features

  • Outside-to-inside flow direction
  • New generation PVDF hollow fiber
  • Nominal pore size of 0.01 μm
  • Typical filtrate quality SDI ≤ 2.5, turbidity ≤ 0.08 NTU

Advantages

  • High tolerance for feed water and high-quality filtrate
  • Smaller footprint design with CAPEX reduction
  • Less energy needed by high flux
  • Longer service life by high fouling resistance and mechanical strength
  • Economical equivalent module for direct replacement for Pall Ultra60 MSA-620A

Applications

  • Portable water
  • Municipal water
  • Industrial process water
  • Reclaimed water reuse
  • Pre-treatment of seawater desalination

Module Dimensions

Pall Ultra60 MSA-620A Equivalent UF Membrane Module Dimensions

Model

L
(mm/inch)

L1 (mm/inch)

D
(mm/inch)

D1 (mm/inch)

W (mm/inch)

Feed/Filtrate port

Concentrate port

TFMSA-60A

2322/91.8

172/6.8

178/7.0

220/8.7

150/5.9

ø60.3 (50A)

ø57.91xP3

Specifications

Model

TFMSA-60A

Effective membrane area

60 m² (646 ft²)

Dry weight

35 kg (77 lb)

Wet weight filled with water

65 kg (143 lb)

Membrane material

PVDF (polyvinylidene fluoride)

Pore size

0.01 μm (150 kDa)

Housing material

UPVC

End caps material

UPVC

Potting material

Epoxy resin

O-rings material

EPDM

Operating and Cleaning Limits

Flow direction

Outside-in

Type of operation

Dead-end flow

Maximum feed flow

Process capacity range

2.2 - 10.0 m3/h (10 - 44 gpm)

Temperature

0-40°C (32-104°F)

Maximum feed pressure (25°C)

0.3 MPa (44 psi)

Maximum trans-membrane pressure

0.3 MPa (44 psi)

Normal operating trans-membrane pressure

0 - 0.2 MPa (0 - 29 psi)

Maximum backwash flow

11.2 m3/h (49 gpm)

Maximum backwash pressure

0.3 MPa (44 psi)

Maximum air scour flow

6.7 Nm3/h (3.9 scfm)

Maximum air scour feed pressure

0.25 MPa (36 psi)

pH continuous operation @ 25°C

2 - 11

pH cleaning @ 25°C

1 - 12

Maximum NaClO

3,000 mg/L

Maximum NaClO exposure (lifetime contact time) as Cl2

1,000,000 mg/L hours

Maximum feed TSS

100 ppm

Maximum feed turbidity

300 NTU

Maximum feed particle size

300 µm

Filtrate SDI15

≤ 2.5

Filtrate turbidity

≤ 0.08 NTU

We offer various UF membrane module equivalents. If you and your customer accept Pall Ultra60 MSA-620A equivalent UF membrane module, please send us an inquiry now.

WechatClose
Wechat
WhatsappClose
Whatsapp