Economical equivalent membranes with quick delivery for replacement in water and wastewater treatment projects.

Products >> Hollow Fiber UF Membrane Module >> PVDF UF Membrane Module

  • DuPont IntegraTec XTP 100 IG Alternative
DuPont IntegraTec XTP 100 IG Alternative

DuPont IntegraTec XTP 100 IG Alternative

Alternative to: DuPont IntegraTec XTP 100 IG UF membrane module 12113146

Alternative Comparison Chart

Parameters Module Alternative Module
Model DuPont IntegraTec XTP 100 IG TFSFX-100P
Dimensions D 225 mm, L 2363 mm D 225 mm, L 2363 mm
Membrane Material PVDF (polyvinylidene fluoride) PVDF (polyvinylidene fluoride)
Pore Size 0.03 µm 0.03 µm
Membrane Area 100 m2 100 m2
Flow Direction Outside-in Outside-in
Type of operation Dead-end flow or cross flow Dead-end flow or cross flow

General Information

TFSFX-100P is manufactured as the alternative to DuPont IntegraTec XTP 100 IG UF membrane module 12113146.
TFSFX-100P ultrafiltration (UF) membrane modules are pressurized modules, which are developed and manufactured for the filtration of surface water, potable water, seawater and industrial wastewater. These UF modules are made of upgraded new generation PVDF hollow fibers with extra permeability than SF series.
TaFlux SFX series UF modules are applied in new systems, as well as directly connected to existing UF systems as replacements, providing high-quality filtrate by removing suspended solids, colloids, pyrogens, bacteria, viruses and other impurities to protect downstream processes.

Features

  • Outside-to-inside flow direction
  • Upgraded new generation PVDF hollow fiber
  • Nominal pore size of 0.03 μm
  • Typical filtrate quality SDI ≤ 2.5, turbidity ≤ 0.1 NTU

Advantages

  • High tolerance for feed water
  • High-quality filtrate
  • Higher capacity by higher effective filtration area with same footprint
  • Longer service life by high fouling resistance and mechanical strength
  • Economical alternative module for direct replacement of DuPont IntegraTec XTP 100 IG

Applications

  • Surface water
  • Potable water
  • Industrial process water
  • Industrial wastewater
  • Reclaimed water reuse
  • Pre-treatment of seawater desalination

Module Dimensions

DuPont IntegraTec XTP 100 IG Alternative UF Module Dimensions

Model

L

L1

D

H

Connector

TFSFX-100P

2363±3 mm

(93.0±0.1 inch)

2133±3 mm

(84.0±0.1 inch)

225 mm

(8.9 inch)

180 mm

(7.1 inch)

DN50

Specifications

Model

TFSFX-100P

Effective membrane area

100 m² (1076 ft²)

Volume

41 L (10.8 gallon)

Dry weight

60 kg (132 lb)

Wet weight filled with water

101 kg (223 lb)

Membrane material

PVDF (polyvinylidene fluoride)

Fiber ID/OD

0.6/1.1 mm (0.02/0.04 inch)

Pore size

0.03 μm

Housing material

UPVC

Clamp material

Stainless Steel

Potting material

Epoxy resin/Polyurethane

Air connector

3/8”

Operating and Cleaning Limits

Flow direction

Outside-in

Type of operation

Dead-end flow or cross flow

Design flux (25°C)

40 - 120 L/m2·h (24 - 71 gfd)

Flux range per module

2.6 - 11.0 m3/h (11.5 - 48.4 gpm)

Temperature

1 - 40°C (34 - 104°F)

Maximum feed pressure (20°C)

0.62 MPa (90.6 psi)

Maximum feed pressure (40°C)

0.47 MPa (68.8 psi)

Maximum trans-membrane pressure

0.21 MPa (30.5 psi)

Backwash flux (25°C)

80 - 120 L/m2·h (48 - 71 gfd)

Maximum backwash pressure

0.25 MPa (36 psi)

Maximum air scour feed pressure

0.25 MPa (36 psi)

Maximum air scour flow

4 - 12 Nm3/h (2.4 - 7.1 scfm)

pH-Continuous operation @25°C

2 - 11

Maximum instantaneous exposure NaClO

4,000 mg/L

Maximum feed TSS

100 ppm

Maximum feed turbidity

300 NTU

Maximum feed particle size

300 µm

Filtrate SDI15

≤ 2.5

Filtrate turbidity

≤ 0.1 NTU

We offer various UF membrane module alternatives. If you and your customer accept DuPont IntegraTec XTP 100 IG alternative UF membrane module, please send us an inquiry now.

WechatClose
Wechat
WhatsappClose
Whatsapp